A wine service cooler should hit predictable serving temperatures, protect aroma and structure, and stay quiet at the pass. This Australia‑specific guide turns regulation context (FSANZ cold‑holding, EEI/GEMS scope), refrigerant choices (R290), and practical layout principles into a plan your team can install, sign off and live with every night.

Search intent: Commercial investigation How‑to • Audience: restaurant owners, bar managers, sommeliers, fit‑out and M&E teams.

Executive summary (60–90 seconds)

  • Service ≠ cellaring. Service coolers aim for ready‑to‑pour temperatures (e.g., whites often 8–12 °C; lighter reds ~14–16 °C). That’s industry practice, not a legal limit; your cold‑holding obligations still apply to any potentially hazardous garnishes or food items nearby. See FSANZ temperature control and the 2‑hour/4‑hour rule (national guidance).
  • EEI & scope. Many commercial wine cabinets are assessed as “refrigerated cabinets” under Australia’s GEMS (Refrigerated Cabinets) Determination 2024 with EEI (Energy Efficiency Index). Some small wine fridges may fall under household appliances. Confirm the registration pathway and “intended use” with suppliers; always choose AU‑registered models where applicable (EnergyRating.gov.au).
  • Natural refrigerants. R290 (propane) is widely used in modern cabinets; it has very low GWP under Australia’s HFC framework and strong efficiency when applied correctly (DCCEEW context).
  • Placement matters (a lot): avoid ovens, combi steamers and west‑facing glass; leave service access and ventilation; isolate from subwoofers; decouple the cabinet from resonant joinery to cut hum.
  • Dual‑zone done right: pick independent zones with separate evaporators/fans (not just baffles). Map your wine list to real shelf positions; verify top‑shelf temperatures under Friday‑night load.

Who this is for (personas)

“45‑seat bistro with glass‑pour program”

Needs a quiet undercounter unit with reliable whites at 9–10 °C and a slightly warmer red zone near 15 °C, plus fast recovery between pours.

“100‑seat dining room with tasting menu”

Needs a taller dual‑zone cabinet near the pass for curated flights, stable temps across shelves, and vibration control near a timber floor and speakers.

Search‑intent alignment: This is a commercial investigation & how‑to guide. It answers “how to choose and place a wine service cooler” with standards, layouts, and calculators—no fluff.

Compliance snapshot (plain English)

TopicWhat to doWhere it comes fromIf you don’t
Temperature control (food safety) Hold potentially hazardous food at 5 °C or colder (or ≥ 60 °C hot). If outside control (e.g., on the pass), use the 2‑hour/4‑hour rule; time is cumulative; discard after > 4 h. FSANZ — temperature controlFSANZ — 2‑hour/4‑hour rule Food safety risk; enforcement actions; wastage (must discard after 4 h).
Refrigerated cabinets EEI (where applicable) Choose cabinets registered for AU supply under the GEMS 2024 determination with EEI declared (or confirm household category). Energy Rating — Refrigerated cabinets Non‑compliant equipment may not be lawfully supplied; often poorer efficiency.
Refrigerants & reporting context Prefer low‑GWP refrigerants (e.g., R290). Australia reports HFC GWPs on an AR4 basis; non‑HFCs such as R290 have very low GWP. DCCEEW — HFC phase‑down Higher environmental impact; potential future retrofit costs.

Service temperatures vs storage (set realistic targets)

Wine is not regulated by FSANZ with a specific °C requirement for service. Temperature targets are industry practice, and you should adjust to your wine list and guest preference. A sensible starting point for service (not cellaring) is:

StyleTypical service rangeCabinet zone targetNotes
Sparkling6–8 °C7 °CUse colder top‑shelf for fast service; avoid freezing necks
Light whites (Riesling, Pinot Grigio)8–10 °C9 °CKeep brightness without muting aromatics
Fuller whites (Chardonnay)10–12 °C11 °CRoom for malolactic‑driven texture
Light reds (Pinot Noir)14–16 °C15 °CPreserve freshness; avoid “jammy” hot noses
Fuller reds (Shiraz/Cabernet)16–18 °C16–17 °CModern dining rooms are warmer; don’t serve at 22 °C

Calibrate with a probe on actual shelves under load. Verify after the room has filled (e.g., 7–8 pm) and again at close—that’s when problems show.

Dual‑zone coolers (what “real” dual‑zone looks like)

  • Independent circuits: Each zone should have its own evaporator and fan(s), not a passive divider. Ask vendors to confirm.
  • Separate probes & controllers: You need individual setpoints and alarms for white/red zones.
  • Shelf mapping: Put sparkling and lighter whites near the coldest air path; reds on shelves with the smallest ΔT swing.
  • Door discipline: Use soft‑close, keep seals new, and split frequently accessed SKUs across doors to cut openings per door.

Vibration, noise & placement (protect aroma and service flow)

Placement rules

  • Avoid ovens, combi steamers, dishwashers and west‑facing glass; heat spikes force fans into louder cycles.
  • Leave manufacturer ventilation clearances; never box‑in exhausts behind solid kickers—use louvres.
  • Isolate from subwoofers and resonant timber; decouple cabinet feet with anti‑vibration pads.
  • Keep the route between prep storage (≤ 5 °C) and service cabinet short for garnishes used with wine service. See FSANZ cold‑holding baseline.

Noise targets

  • Ask for dB(A) at 1 m and the test conditions; typical bar‑side targets are ≤ 55–60 dB(A).
  • When cabinets must be near guests, consider remote condensing if the model supports it.
  • Plan a service panel in millwork for condenser cleaning—dirty coils make everything louder.

Specs to shortlist (what to ask before you buy)

SpecGood targetWhy it mattersHow to verify
Zones & controlTrue dual‑zone; independent probes/controllersDifferent service temps for whites/redsDatasheet; demo control panel
Shelf temp stability±1–2 °C swing at rated climate classPredictable serviceProbe top vs middle shelves at peak
Climate classClass 3 for stable rooms; Class 4 near heat/sunHolds temp in your real ambientData plate and datasheet
EEI / MEPS (scope)GEMS 2024 registration where applicableLegal supply; efficiency baselineSupplier declares AU registration or household scope
RefrigerantR290 (propane)Very low GWP; strong efficiencyDatasheet; safety clearances
Vibration controlBalanced fans; anti‑vibration padsProtects aroma; lowers noiseInspect feet/mounts; listen under load
LightingLow‑heat LED, dimmableAvoids localised heating; presents labelsCheck lumen & CRI; heat near glass
Capacity & layoutReal bottle capacity with your mixNo surprises after installMock‑load a shelf with 750 mL + magnums

Capacity & glass‑pour calculator

Plan capacity by seats and pour rates. Use the quick calculator below to right‑size a service cabinet and decide if you also need a back‑up bar fridge for overflow.

Recommended open‑bottle stock per SKU: whites bottles • reds bottles • Total initial load: bottles (plus back‑up in a bar fridge if space is tight).

This is a service calculator. Keep unopened back‑up stock in a separate fridge (or cellar) to avoid over‑opening; rotate nightly.

Layout diagrams (avoid the classic traps)

Prep ≤ 5 °C Pass / service Wine service cooler Oven/heat Window Rear/side ventilation clearance Anti‑vibration feet / pads

Keep the route from prep ≤ 5 °C to service short (FSANZ baseline applies to any food items); site your wine service cooler away from heat and sun; preserve clearances and vibration isolation.

Running‑costs calculator (simple)

Estimate annual energy cost with: kWh per 24 h × tariff ($/kWh) × 365. Real‑world use varies with ambient, door openings and setpoint. Compare units in the same climate class and capacity.

Estimated annual cost: $317Sensitivity: heavy use (+20% opens) ≈ $333, light use (–20%) ≈ $301.

Installation & commissioning checklist (pass on first inspection)

ItemWhy it mattersPass/fail test
Ventilation clearances respected Prevents overheating and noise ramping Measure rear/side gaps; verify louvres not solid panels
Independent zone control verified Stable white/red service temps Probe top/middle shelves at peak; ΔT ≈ ±1–2 °C
Vibration isolation installed Protects aroma; reduces hum Anti‑vibration pads; cabinet not hard‑fixed into timber
Dedicated power per cabinet Avoids nuisance trips Separate circuit from coffee/oven loads
Condenser & filters accessible Duty and efficiency over time Service panel opens without removing cabinet
Food safety signage at pass FSANZ cold‑holding applies to garnishes/foods 2‑hour/4‑hour quick card; logs available

Case study — “Mid‑size restaurant adding a 60‑bottle dual‑zone at the pass” (Adelaide)

The brief: A 90‑seat dining room wanted a 60‑bottle wine service cooler within 3 m of the pass to support a by‑the‑glass program (5 whites, 5 reds), with a separate back‑up bar fridge for overflow. A combi steamer sat 2 m to the right; afternoon sun hit the façade.

What we found

  • Late‑service ambient near the planned spot hit ~29–31 °C; timber floor amplified compressor hum.
  • Joinery drawings boxed the rear grille and had no service panel for cleaning.
  • Front‑of‑house speakers sat under the counter, sharing the plinth volume with the fridge intake.

What changed

  1. Class 4 dual‑zone selected for temperature headroom; independent controllers verified.
  2. Louvred service panel added with 150 mm rear clearance; toe‑kick vents cut; anti‑vibration pads under feet.
  3. Speakers relocated and the subwoofer isolated in a separate, baffled compartment.
  4. Window film strip added to cut PM sun on the cabinet top; temperature probes installed at top/middle shelves for first two weeks.

Result: Whites held 9–10 °C; reds 15–16 °C during the peak hour with a ΔT swing within ±1.5 °C. Noise dropped below 55 dB(A) at 1 m; weekly condenser cleaning took 5 minutes via the new panel.

FAQs (direct answers)

Do wine service coolers have to meet Australia’s EEI/MEPS rules?

Often yes, sometimes no. Many are covered as “refrigerated cabinets” under the 2024 GEMS determination (EEI). Some smaller units may be registered under household appliance rules. Confirm the registration pathway with your supplier and choose AU‑registered models where applicable. See EnergyRating.gov.au for scope pages.

What temperature should I set for whites and reds?

For service, a practical start is whites 8–12 °C and lighter reds 14–16 °C (adjust for style and guest preference). Always verify on actual shelves at peak hour.

Will R290 refrigerant make my cabinet unsafe?

R290 is widely used in modern commercial refrigeration. It has very low GWP and, when applied within certified charge and clearance limits, is safe and efficient. See DCCEEW context on Australia’s HFC phase‑down and low‑GWP alternatives.

Why is my cabinet noisy some nights?

Warm ambient and blocked grilles force high fan speeds. Fixes: clear ventilation, clean the condenser, add anti‑vibration pads, and avoid heat sources and subwoofers sharing the plinth volume.

Can I keep garnishes in the wine cooler?

Yes, if space allows and the product requires cold holding. Remember FSANZ: potentially hazardous food must be ≤ 5 °C or apply the 2‑hour/4‑hour rule if briefly out of control; time is cumulative.

Sources & further reading (official)

  • FSANZ — Temperature control (≤ 5 °C / ≥ 60 °C): official page
  • FSANZ — 2‑hour/4‑hour rule (national explainer + InfoBite PDF): overview
  • Energy Rating (Australia) — Refrigerated cabinets (EEI under GEMS 2024): product scope & guidance
  • DCCEEW — HFC phase‑down & refrigerant GWPs (AR4 basis): department page

We cite stable government sources and avoid short‑lived links. Always confirm current datasheets with your supplier before purchase.

Pillar & cluster model (how this boosts rankings)

This guide is a cluster page under our commercial refrigeration pillar. Interlink it with:

About the authors (authority & review)

Written by the KW Commercial Kitchen editorial team for Australian restaurants and bars. Reviewed against FSANZ food safety guidance, Energy Rating (GEMS 2024) materials and DCCEEW refrigerant context. Layout and commissioning notes reflect common Australian fit‑out practices referenced in manufacturer manuals and on‑site checklists.


Next steps (CTA)

Have drawings and a wine list? Send cabinet location, ambient snapshots (pre‑rush vs peak), nearby heat sources, and your by‑the‑glass SKUs; we’ll reply with a climate‑class recommendation, ventilation notes and a capacity plan.

Compliance note: This guide references national standards and government publications (FSANZ; Energy Rating; DCCEEW). Always check any additional state/territory or local council requirements during design and permit stages.

© 2025 KW Commercial Kitchen — Australia