Turbo Air Refrigerated Sandwich Display Case 1500mm TOS-1500
1500 × 900 × 840mm
Cold Display Cabinets

74 results

1500 × 900 × 840mm

1500 × 900 × 920mm

1500 × 900 × 1055mm
1500 × 900 × 920mm

1800 × 900 × 840mm
1800 × 900 × 920mm

1800 × 900 × 1055mm
1800 × 900 × 920mm

900 × 900 × 840mm
900 × 900 × 920mm

900 × 900 × 1055mm
900 × 900 × 920mm






1330 × 602 × 1970mm

1580 × 602 × 2080mm

905 × 800 × 1520mm

1350 × 900 × 2115mm

1080 × 602 × 1970mm

900 × 600 × 1520mm

1830 × 740 × 2000mm

1220 × 740 × 2000mm

1330 × 765 × 2130mm
An open display fridge gives customers direct front access to packaged chilled products, making it useful for fast self-selection where doors would interrupt traffic. Its open-front convenience depends on a stable refrigerated air curtain, disciplined shelf loading and room conditions that suit the cabinet.
Multideck shelving can present several product levels within a compact run. Set shelf heights from real packs and customer reach, keep labels visible and plan replenishment from the staff route without blocking shoppers at the front.
Open display fridges are also searched for as open chillers, open-deck fridges and grab-and-go fridges. The current range includes tall multideck cabinets, lower promotion showcases and listings with doors. Check the exact access format as well as width, depth and height before shortlisting.
Turbo Air TOM500-2 measures 500 × 650 × 1510 mm; TOM500-4 measures 500 × 650 × 1910 mm. These two models have the same listed width and depth, with a 400mm height difference. Their model suffixes alone do not establish a shelf count.
For a lower cabinet example, Thermaster DC-900C measures 900 × 600 × 1520 mm. The taller Thermaster OC-915 measures 975 × 770 × 2070 mm: 75mm wider, 170mm deeper and 550mm taller. All dimensions here are external W × D × H; check access, ventilation and service clearances separately in the exact model instructions.
Thermaster DC-900C lists 253L gross volume, while OC-915 lists 405L net volume. Those headline litres use different measurement bases. True TOAM-30GS-HC~NSL01 shows the distinction within one cabinet: 328L net and 723L gross volume, with four supplied shelves.
For a comparison using the same capacity labels, True TOAM-48GS-HC~TSL01 lists 547L net and 963L gross volume, also with four supplied shelves. The two True models measure 762 × 738 × 1994 mm and 1220 × 757 × 1994 mm respectively. Check shelf dimensions and your pack sizes alongside the capacity figures.
Thermaster PDK-1360 is listed as a promotion showcase. PDK-1360D is explicitly listed as a promotion showcase with two doors. Both measure 1360 × 1095 × 930 mm. A shared footprint or category listing does not mean identical customer access.
Tecnodom TDST90-CA-125BD is listed as a remote display with doors, measuring 1350 × 900 × 2115 mm. Confirm the refrigeration installation scope and required services with the supplier and installer. A listed electrical connection alone does not establish that a remote cabinet is a self-contained plug-in unit.
OC-915 lists a maximum ambient temperature of 25°C at 60% relative humidity. That describes the room around the cabinet. DC-900C lists a cabinet operating range of +3 to +8°C, while the two True TOAM examples list 0.5 to 3.3°C. Check the selected model’s permitted products and operating conditions against the storage requirements for what you intend to sell.
For other chilled display formats, compare Countertop Cold Displays for counter placement, Deli Display Fridges for deli-format cabinets, and Cake Display Fridges for cake presentation. Retail Display Fridges provides further retail cabinet choices. Confirm the actual doors, shelves and product suitability on each model; ranges can overlap.
Key factors to consider before purchasing. Our team can help you find the right fit — call or get a quote anytime.
Turbo Air TOM500-2 measures 500 × 650 × 1510 mm; TOM500-4 measures 500 × 650 × 1910 mm. Compare the listed cabinet height separately from width and depth.
True TOAM-30GS-HC~NSL01 lists both volumes for one cabinet, with four supplied shelves. Keep each capacity label attached when comparing models.
Thermaster PDK-1360 and PDK-1360D both measure 1360 × 1095 × 930 mm. PDK-1360D is explicitly listed with two doors; check the selected configuration.
Submit your kitchen requirements — our equipment specialists will send you a tailored shortlist of open display fridges that fits your budget, venue type and compliance needs.
Our team can recommend cabinet sizes, airflow performance and refrigeration configurations suited to Australian commercial venues.
Compare exact model specifications and installation requirements before ordering.
Standards & Compliance
Ambient temperature, humidity, sunlight and nearby draughts can disturb open-front operation. Check the nominated environment before placing the cabinet near entrances, windows or heat-producing areas, and preserve the specified ventilation clearances.
Products must stay behind load limits and away from discharge and return-air openings. Train staff to rotate stock without pushing packs into the air path, and use night covers or operating controls only as directed for the selected unit.
FAQ
Check the exact cabinet’s permitted use and operating range against the dairy product’s storage instructions. The range contains models with different temperature specifications: DC-900C lists +3 to +8°C, while True TOAM-30GS-HC~NSL01 lists 0.5 to 3.3°C. The open-display format alone does not establish suitability for every dairy product.
Packaging alone does not establish suitability for raw meat. Confirm that the exact cabinet is intended for the proposed product and can meet its required storage conditions. Obtain the manufacturer’s application guidance before choosing a model for this use.
Installation instructions can restrict heat sources, sunlight and external airflow. Bromic’s multideck manual, for example, excludes direct sunlight and warm draughts or open doors, and requires clear air inlets and outlets. Check the exact model instructions against the proposed location.
Confirm inclusion on the exact model and quote. A category listing does not establish whether a night blind is included, optional or unavailable. Where a cover is supplied, follow its operating instructions and confirm how it is used during closed hours.
Use the selected model’s maintenance schedule. Bromic’s multideck manual specifies monthly condenser-coil and filter cleaning for the models it covers. Do not apply one interval to every brand; follow the relevant manual and use qualified service personnel for work outside the operator instructions.
It suits packaged chilled products that customers select frequently in a room that meets the cabinet’s ambient requirements. Choose another format when strong draughts, heat, sunlight or operating conditions would repeatedly disturb the air curtain, or when direct access is unnecessary.
The cabinet relies on controlled refrigerated airflow across an open front. Excess heat, humidity, sunlight or draughts can disrupt that curtain and create uneven conditions, so the proposed location must stay within the stated operating environment.
Keep packs behind shelf load limits, leave discharge and return openings clear and prevent labels or signs from projecting into airflow. Use shelf heights that fit the products, and replenish in controlled quantities rather than pushing stock forward beyond the marked boundary.
Move food to suitable refrigeration, isolate the cabinet as instructed and remove permitted shelves and fittings. Clean crumbs and labels from grilles, wipe and dry surfaces, inspect openings for obstruction and reinstall parts without covering the airflow path.
Why KW
For an open-front display, KW can review customer traffic, pack facings and shelf access alongside the room conditions that protect the air curtain. Call 1300 001 366 to discuss a multideck merchandising position and replenishment route.
Deep Dive
Technical depth from KW's commercial kitchen specialists.
Keep the cabinet’s air paths clear and follow its loading limits. The Bromic multideck manual, which covers its FHM range, requires space for air circulation and unobstructed fans and top and bottom grilles.
Follow the model’s start-up and loading instructions, including any pre-cooling requirement. Confirm whether the unit is intended to hold already chilled products or has a documented pull-down application. Compressor size alone does not establish recovery performance.
Confirm whether the selected cabinet has self-contained refrigeration or needs a remote installation. Ask for the complete refrigeration, electrical, ventilation and commissioning requirements before ordering; do not assume that every model uses the same installation arrangement.
Match the exact model’s ambient limits and installation instructions to the site. Bromic’s multideck instructions exclude direct sunlight and warm draughts or open doors. Check nearby heat sources and airflow before choosing the cabinet position.
Compare documented energy consumption for the exact models under equivalent test conditions and display requirements. Rated input power does not state daily energy use. Check whether a night cover is included and follow its instructions; do not assume a universal saving from cabinet style or refrigerant type.
Keep supply and return openings clear and load every shelf within its marked boundary. Avoid signs, packaging or protruding packs that divert airflow, and investigate repeated warm spots rather than compensating by crowding products elsewhere.
Transfer food as required, isolate the cabinet according to its instructions and remove approved shelves or fittings. Clear crumbs and labels from grilles, wipe surfaces without flooding electrical areas, then refit dry parts without covering air passages.
Use this format where shoppers need quick access to packaged chilled lines and the venue can maintain suitable room conditions. Enclosed-door refrigeration may be more appropriate where doors support environmental stability or where customer access is less frequent.
Arrange high-turnover lines within easy reach, keep date labels accessible to staff and replenish from a route that does not trap customers at the cabinet. Rotate stock from behind or by controlled front access without extending products beyond load lines.
Review broader refrigeration categories, compare other chilled cabinet formats and coordinate merchandising through the wider display showcase range.