Countertop Cold Display Fridges (Australia, 2025) — Power, Ventilation & POS Layouts That Actually Fit
A countertop display fridge should do three things: hold ≤ 5 °C during service, sell product at the point‑of‑sale, and avoid cooking your counter with hot exhaust. This Australia‑specific guide turns FSANZ rules and real café conditions into a clear, layout‑first plan you can install and pass inspection.
Search intent: Commercial investigation How‑to • Audience: small cafés, bakeries, convenience/QSR, fit‑out teams.
Executive summary (60–90 seconds)
- Compliance baseline: Potentially hazardous food must be kept at 5 °C or colder (or 60 °C or hotter). If displayed out of temperature control, use the 2‑hour/4‑hour rule—time is cumulative. Source: FSANZ temperature control and 2‑hour/4‑hour guidance.
- Energy regulation: Australia’s GEMS (Refrigerated Cabinets) Determination 2024 regulates refrigerated cabinets via EEI (Energy Efficiency Index). Choose models that declare EEI class and are registered for sale in Australia. Source: EnergyRating.gov.au.
- Match climate class to your ambient: Class 3 ≈ 25 °C/60% RH (AC indoor), Class 4 ≈ 30 °C/55% RH (warmer POS, near doors/coffee), Class 5 ≈ 40 °C/40% RH (very hot). Select by your hottest realistic condition.
- Don’t choke the vents: Respect intake/exhaust clearances; never box rear‑exhaust models in millwork; allow service access to clean the condenser.
- Plan power early: Most units are single‑phase; give each a dedicated GPO on a clean circuit; avoid daisy‑chaining with grinders or microwaves.
Why countertop displays are different (and easy to get wrong)
Under‑counter or upright units enjoy more airflow; countertop units often sit in tight joinery next to coffee machines, EFTPOS, and impulse displays. The result: warm recirculating air at the grille, drifting shelf temperatures, and fans that run constantly. This guide shows how to avoid the classic traps while meeting Australia’s rules.
Compliance snapshot (plain English)
Topic | What to do | Where it comes from | If you don’t |
---|---|---|---|
Temperature control | Hold ≤ 5 °C (or ≥ 60 °C). If outside control, apply the 2‑hour/4‑hour rule; time is cumulative; discard after > 4 h. | FSANZ — temperature control • FSANZ — 2‑hour/4‑hour rule | Food safety risk; enforcement actions; product wastage. |
Refrigerated cabinets EEI | Choose EEI‑compliant refrigerated display cabinets (GEMS 2024 in force). | Energy Rating — Refrigerated cabinets | Non‑compliant products cannot be legally supplied; higher running costs. |
Cleaning & maintenance | Keep condenser and airways clean; maintain door gaskets; verify shelf temps with a probe in service conditions. | FSANZ general hygiene and maintenance principles | Temperature drift, energy spikes, and hygiene issues. |
FSANZ provides national standards; always confirm additional state/territory or council requirements (e.g., record‑keeping forms, inspection checklists).
Climate class & ambient (choose once, avoid fogging all summer)
Climate class describes the ambient temperature and relative humidity in which the cabinet is tested to maintain performance. AU practice follows the AS 1731/ISO 23953 conventions. Choose by your hottest realistic condition, not just winter averages.
Class | Ambient (°C / RH) | Typical POS locations | Why it matters |
---|---|---|---|
Class 3 | ~25 °C / 60% RH | Air‑conditioned POS, away from doors and heat | Quieter and efficient; sufficient for stable stores |
Class 4 | ~30 °C / 55% RH | Near swing doors, west sun, coffee machine, queue lights | Holds ≤ 5 °C in tougher ambient; check noise and energy |
Class 5 | ~40 °C / 40% RH | Events/outdoor counters, very hot shops | Highest duty; only if needed due to cost/noise |
Power & ventilation (the checklists that save service calls)
Electrical planning
- Single‑phase power; provide a dedicated GPO per unit.
- Avoid sharing circuits with grinders/microwaves to reduce nuisance trips.
- Check nameplate amperage; allow 20–25% headroom on the circuit.
- Route cords to avoid pinch points in millwork; keep plug accessible.
Airflow & service space
- Do not box in rear‑exhaust models. Leave the datasheet clearance to wall/joins and a removable panel for cleaning.
- For front‑intake/front‑exhaust models, keep the grille free of signage and napkin caddies.
- Measure ambient at the grille during rush; if > 30 °C, consider a Class 4 cabinet or move heat sources.
- Schedule monthly condenser cleaning; dust kills performance.
Keep the route from back‑of‑house ≤ 5 °C storage short; site the countertop display fridge away from espresso heat; preserve intake/exhaust clearances in millwork.
POS layout matrix (pick the pattern that fits your counter)
Scenario | Recommended intake/exhaust | Climate class | Width & depth | Notes |
---|---|---|---|---|
Small counter, tight aisle | Front‑intake/front‑exhaust | Class 3 | ≤ 900 mm W; ≤ 600 mm D | Keep grille free; avoid card stands in front |
Near entrance, afternoon sun | Front‑intake/rear‑exhaust with shroud louvres | Class 4 | 900–1200 mm W | Add a window film strip; probe temps at 3–5 pm |
Long service line + drinks add‑ons | Rear‑exhaust with 150–200 mm clearance | Class 3–4 | 1200–1500 mm W | Combine with a back‑bar for overflow drinks |
High‑humidity store | High‑duty fan path; clear side vents | Class 4 | As required | Curved glass reduces visible droplets |
Specs to shortlist (what to ask before you buy)
Spec | Good target | Why it matters | How to verify |
---|---|---|---|
Climate class | 3 for stable POS; 4 near doors/heat/sun | Holds ≤ 5 °C in real ambient | Check the data plate & datasheet |
EEI / MEPS compliance | Declared EEI class; registered for AU supply | Legal supply; lower running costs | Ask for Energy Rating registration details |
Refrigerant | R290 (propane) | Very low GWP; efficient | Confirm charge & safety clearances |
Ventilation | Clearances per datasheet; service panel in joinery | Prevents overheating & fogging | Millwork drawings show louvres/cut‑outs |
Shelf temperature | ≤ 5 °C across shelves at rated class | FSANZ baseline | Probe top & bottom shelves during rush |
Noise | < 55–60 dB(A) at 1 m (typical) | Comfort at POS | Ask for measurement method/conditions |
Cleaning access | Front‑cleanable condenser preferred | Less downtime; stable temps | See manual; try the filter panel |
Dimensions | Widths 600–1500 mm; depth matched to counter | No overhang; keeps aisles clear | Mock‑up with cardboard before purchase |
Running‑costs calculator (simple)
Estimate annual energy cost with: kWh per 24 h × tariff ($/kWh) × 365
. Real use varies with ambient, door openings and setpoint. Compare similar widths and climate classes only.
Estimated annual cost: $416 • Sensitivity: heavy use (+20% opens) ≈ $437, light use (–20%) ≈ $395.
Case study — “90‑cm counter at a busy espresso bar” (Brisbane)
The brief: Add a countertop display fridge for sandwiches and small cakes to a 900‑mm‑deep counter with a La Marzocco espresso machine and two grinders. Afternoon sun hits the window from 3–4:30 pm.
What we found
- Ambient at the proposed cabinet position hit 29–31 °C during rush due to coffee heat and door swings.
- The first millwork drawing boxed in the rear grille; no service panel for cleaning.
- Shared circuit with the microwave caused nuisance trips in tests.
What changed
- Switched to Class 4 cabinet to keep ≤ 5 °C at the top shelf in PM rush.
- Added a louvred shroud (150 mm rear clearance) and a removable service panel.
- Dedicated GPO for the cabinet; microwave moved to a separate circuit.
- Anti‑glare window film to reduce late‑afternoon heat gain on the cabinet top.
Result: Stable shelf temperatures, fewer fogging incidents, and faster evening reset. Inspection passed on first visit with clear temperature logs at POS.
Installation & hygiene checklist (pass on first inspection)
Item | Why it matters | Pass/fail test |
---|---|---|
Cabinet holds ≤ 5 °C across shelves | FSANZ temperature control; product safety | Probe top & bottom shelves during rush; log readings |
2‑hour/4‑hour procedure visible | Covers periods out of refrigeration | Quick card at POS; discard > 4 h |
Ventilation clearances respected | Prevents overheating/fogging | Measure rear/side gaps; grille unobstructed |
Gaskets seal & doors align | Energy & temperature stability | Paper test on door; replace worn gaskets |
Condenser & airways clean | Maintains performance & efficiency | Monthly brush/vacuum; set calendar reminders |
Dedicated power | Avoids nuisance trips | Separate circuit from grinders/microwave |
FAQs (direct answers)
What temperature should a countertop display fridge run at?
Keep potentially hazardous food at 5 °C or colder. That’s the FSANZ baseline for cold holding.
Can I use the 2‑hour/4‑hour rule at the POS?
Yes, when food is outside refrigeration, but time is cumulative: up to 2 h (refrigerate or use), 2–4 h (use immediately), more than 4 h (discard). Treat it as a safety net, not a daily operating strategy.
Do countertop display fridges need to meet EEI/MEPS rules?
If they fall under refrigerated cabinets, they are covered by the GEMS 2024 determination and assessed via EEI. Choose models registered for supply in Australia.
How do I know if I need Class 3 or Class 4?
Measure the ambient at the grille during your busiest time. If it reaches ~30 °C or you’re near doors/coffee/PM sun, choose Class 4 for temperature headroom.
Should I choose curved or square glass?
Curved sheds droplets and glare better; square maximises shelf area. Choose for your light, humidity and product sizes.
Sources & further reading (official)
- FSANZ — Temperature control (≤ 5 °C / ≥ 60 °C): official page
- FSANZ — 2‑hour/4‑hour rule: overview • InfoBite PDF
- Energy Rating (Australia) — Refrigerated cabinets (EEI under GEMS 2024): product scope & guidance
- Climate class context used in AU (AS 1731 / ISO 23953 conventions). Check your model datasheet for the exact rating.
We link only to official or manufacturer sources and avoid short‑lived pages. Always confirm current datasheets before purchase.
Pillar & cluster model (how this boosts rankings)
This article is a cluster page under our refrigeration pillar. Pair it with:
- Sink bench size & layout (BOH flow) — reduces time outside ≤ 5 °C before display.
- Cake display fridges (climate class & EEI) — for larger patisserie runs.
- Bar fridges — for drinks overflow and fast service at the pass.
About the authors (authority & review)
Written by the KW Commercial Kitchen editorial team for Australian cafés and bakeries. Reviewed for accuracy against FSANZ guidance and Energy Rating materials. Layout and commissioning notes reflect common Australian fit‑out practices referenced in manufacturer manuals and site checklists.
Next steps (CTA)
Have drawings already? Send counter width, ambient snapshots at rush, and the nearest heat sources; we’ll reply with a climate‑class recommendation and ventilation notes.