A backbar fridge should chill fast, stay quiet, and survive the hottest hour of the night without fogging or tripping breakers. This Australia‑specific guide turns FSANZ rules (for potentially hazardous garnishes), the 2024 EEI framework, and real bar heat‑load patterns into a layout you can install and pass inspection.

Search intent: Commercial investigation How‑to • Audience: bars, pubs, clubs, hotels, function venues, fit‑out teams.

Executive summary (60–90 seconds)

  • Compliance baseline: Drinks themselves are rarely “potentially hazardous”, but garnishes and prepped ingredients (cut citrus, fresh mixes, dairy) must be held at 5 °C or colder (or 60 °C or hotter). If they leave temperature control briefly, apply the 2‑hour/4‑hour rule (time is cumulative). See FSANZ temperature control and the 2‑hour/4‑hour rule.
  • Energy regulation: Many backbar/underbar units are “refrigerated cabinets” under Australia’s GEMS (Refrigerated Cabinets) Determination 2024 and are assessed via EEI. Buy models registered for supply in Australia (see EnergyRating.gov.au “Refrigerated cabinets”).
  • Match climate class to ambient: Behind‑bar air is hotter than the dining room. Choose Class 4 (≈ 30 °C/55% RH) near dishwashers, coffee or doorways; Class 3 (≈ 25 °C/60% RH) only in cooler bars; Class 5 (≈ 40 °C/40% RH) is high‑duty for very hot sites or events.
  • Quiet ≠ weak: You can reduce noise without starving the condenser—use remote systems or add louvred service panels, not solid doors over exhaust grilles.
  • Layout rule: keep air moving, not recirculating. Leave service gaps and cleaning access; group heat sources thoughtfully; log temperatures during the peak hour.

Personas (write for a real bar)

“High‑turnover sports bar”

Needs fast pull‑down after deliveries, low noise near TVs, and room to service condensers without moving the whole bar. Priority: duty rating and airflow.

“Cocktail venue with garnishes”

Needs precise ≤ 5 °C storage for cut fruit and dairy, glass doors for product visibility, drawers for prep, and a short route to the pass.

Compliance snapshot (plain English)

TopicWhat to doWhere it comes fromIf you don’t
Temperature control (garnishes/ingredients) Hold ≤ 5 °C (or ≥ 60 °C). If briefly outside control, use the 2‑hour/4‑hour rule—time is cumulative; discard > 4 h. FSANZ — temperature controlFSANZ — 2‑hour/4‑hour rule Food safety risk, wastage, potential enforcement actions.
Refrigerated cabinets EEI Select units compliant with GEMS 2024 (EEI‑based). Ask suppliers for AU registration details. Energy Rating — Refrigerated cabinets Non‑compliant models can’t be legally supplied; usually higher running costs.
Cleaning & maintenance Keep condensers clean; replace gaskets; verify shelf temps during peak hour (probe top shelf). FSANZ general hygiene/maintenance principles Temperature drift, energy spikes, service calls.

Climate class & ambient (behind‑bar reality)

Behind‑bar ambient can sit 3–8 °C hotter than the dining room once the crowd arrives. Use climate class to choose a cabinet that holds temperature in your worst hour—not only at midday.

ClassAmbient (°C / RH)Best forNotes
Class 3 ~25 °C / 60% RH Cool, well‑ventilated bars with remote heat sources Quiet/efficient; confirm temps on the top shelf during peak
Class 4 ~30 °C / 55% RH Most Australian bars: near glass washers, espresso, doors Higher duty; check noise and energy draw
Class 5 ~40 °C / 40% RH Very hot bars, events, partial outdoor exposure Only when needed; expect more noise and cost

Heat & airflow (layout patterns that work)

Prep ≤ 5 °C Pass / service Backbar fridge Glass washer Door Rear/side ventilation clearance Louvred service panel

Don’t box‑in exhausts. Leave the datasheet clearance and add a louvred service panel so you can clean the condenser. Keep heat sources (glass washer, espresso) spaced from the fridge intake.

Placement ruleWhyHow to check
Keep rear/side clearances Prevents recirculation and compressor overheat Measure against the datasheet; add removable panels
Avoid glass washer & espresso heat Hot, humid exhaust drives temp drift & frosting Probe intake grille during peak hour
Vent the plinth Solid base traps hot air Louvre cut‑outs; leave toe‑kick gaps
Group by duty & noise Put loudest units away from seating Check dB(A) at 1 m; plan zoning

Specs to shortlist (what to ask before you buy)

SpecGood targetWhy it mattersHow to verify
Climate class Class 4 for most bars; Class 3 only in cool sites Holds temperature in real ambient Data plate & manufacturer datasheet
EEI / MEPS compliance Registered to GEMS 2024; EEI declared Legal supply; energy baseline Ask for AU registration details
Refrigerant R290 (propane) Very low GWP; efficient Check charge & safety clearances in manual
Doors vs drawers Drawers for prep; doors for bottles Service speed & ergonomics Trial with a crate of bottles/pans
Glass vs solid Glass for merchandising; solid for energy/noise Visibility vs efficiency trade‑off Compare kWh/24 h in same class
Noise ~55–60 dB(A) at 1 m (typical) Comfort near patrons Ask for measurement method/conditions
Cleaning access Front‑cleanable condenser or easy pull‑out Less downtime; stable temps Open the grille; try the filter
Corrosion resistance Coated coils; stainless construction Coastal venues & wet bars Spec sheet; warranty terms

Noise planning (keep the vibe, not the hum)

Reduce noise without choking airflow

  • Use louvred doors and side vents—not solid doors—over the condenser area.
  • Decouple the cabinet from resonant joinery with anti‑vibration pads.
  • Zone the loudest units away from seated areas and microphones/DJ booths.

When to go remote

  • In long bars with many fridges, remote condensing can cut heat & noise.
  • Plan drains, line‑sets, and service access; check local building services rules.
  • Budget for install and future maintenance access panels.

Energy & running‑costs (simple calculator)

Running cost ≈ kWh per 24 h × tariff ($/kWh) × 365. Actual energy depends on ambient, duty class, door openings, setpoints and condenser cleanliness. Use this quick calculator to estimate and compare units in the same climate class.

Estimated annual cost: $526Sensitivity: heavy use (+20% opens) ≈ $552, light use (–20%) ≈ $500.

Layout matrices (pick a pattern and build around it)

ScenarioRecommended intake/exhaustClimate classDoors/DrawersWhy it works
Busy sports bar, long straight backbar Rear‑exhaust with 150–200 mm clearance; louvred panels Class 4 Glass doors for bottles High duty & visibility; easy condenser service
Compact cocktail bar with prep Front‑intake/front‑exhaust underbench Class 4 Drawers for GN pans; one glass door Breathes from the front; keeps prep cold
Partial outdoor / event bar High‑duty airflow path; weather‑aware shrouds Class 5 Solid doors; lockable Resists heat spikes; protects stock

Installation & commissioning checklist (pass on first inspection)

ItemWhy it mattersPass/fail test
Garnishes stored ≤ 5 °C; logs available FSANZ temperature control Probe top drawer/shelf at peak; record
Ventilation clearances respected Prevents overheat & frosting Measure rear/side gaps; louvres, not solid doors
Dedicated power per fridge Avoids nuisance trips under load Separate circuits from glass washer/espresso
Gaskets seal; doors align Energy & temperature stability Paper test; replace worn gaskets
Condenser/filters clean & accessible Keeps duty and EEI performance Monthly brush/vacuum; calendar reminder
Record 2‑hour/4‑hour procedure For brief periods out of control Quick card at service; discard > 4 h

Case study — “150‑seat sports bar, coastal NSW”

The brief: Three service points across a 12‑metre backbar, with a glass washer and coffee at the centre station. Friday nights pushed behind‑bar ambient to ~30 °C and the fridges nearest the washer struggled on top shelves.

What we found

  • Solid doors over the condenser area trapped hot air; no service panel.
  • All fridges were Class 3; top‑shelf bottles warmed during the fourth quarter of games.
  • Shared circuits with the glass washer caused occasional trips.

What changed

  1. Up‑spec to Class 4 at the two hottest positions; kept Class 3 further from heat.
  2. Replaced solid doors with louvred panels and added 150 mm rear clearance for airflow.
  3. Dedicated circuits for each fridge bank; separated glass washer and espresso.
  4. Monthly cleaning schedule for condensers; staff trained to log top‑shelf temps at 21:00.

Result: Stable bottle temps at peak hour, fewer call‑outs, and a quieter bar zone near seating.

FAQs (direct answers)

Do beer fridges need to meet Australia’s EEI/MEPS rules?

If they fall under refrigerated cabinets, yes—they’re covered by the GEMS 2024 determination and assessed via EEI. Choose models registered for AU supply.

Which climate class should I pick for a bar—3, 4 or 5?

Class 4 suits most Australian bars because behind‑bar ambient is hotter. Use Class 3 only in cool, well‑ventilated sites; Class 5 for very hot or partial outdoor bars.

How do I keep noise down without starving the fridge?

Use louvred service panels and leave clearances. Solid doors over exhaust grilles trap heat and increase noise as fans ramp.

Do drinks need to be at ≤ 5 °C?

Bottled alcohol isn’t “potentially hazardous”, but garnishes and dairy/juice mixes are. Store them at ≤ 5 °C and apply the 2‑hour/4‑hour rule if briefly out of control.

Drawers or doors for backbar?

Drawers are ideal for prep (GN pans). Doors are best for bottles and quick visual stock checks.

Sources & further reading (official)

  • FSANZ — Temperature control (≤ 5 °C / ≥ 60 °C): official page
  • FSANZ — 2‑hour/4‑hour rule: overviewInfoBite PDF
  • Energy Rating (Australia) — Refrigerated cabinets (EEI under GEMS 2024): product scope & guidance
  • Climate class context used in AU (AS 1731 / ISO 23953 conventions). Check your model datasheet for the exact rating.

We link only to official or manufacturer sources and avoid short‑lived pages. Always confirm current datasheets before purchase.

Pillar & cluster model (how this boosts rankings)

This article is a cluster page under our refrigeration pillar. Pair it with:

About the authors (authority & review)

Written by the KW Commercial Kitchen editorial team for Australian hospitality venues. Reviewed for accuracy against FSANZ guidance and Energy Rating materials. Layout and commissioning notes reflect common Australian fit‑out practices referenced in manufacturer manuals and site checklists.


Next steps (CTA)

Already have drawings? Send backbar lengths, ambient snapshots (pre‑rush vs peak), nearby heat sources and preferred door/drawer mix; we’ll reply with a climate‑class recommendation, venting notes and a short‑list.

Compliance note: This guide references national standards and government publications (FSANZ; Energy Rating). Always check any additional state/territory or local council requirements during design and permit stages.

© 2025 KW Commercial Kitchen — Australia